M-PM70A 7' inch Vital signs Patient Monitor
6 Multi-parameters Patient monitor --- Multi-parameter Patient monitor

Function:
1.7" color TFT display, high resolution: 640X480dpi;
2.Full Separated para boards: Main board, ECG board, NIBPboard, SpO2 board, can guarantee the acccuracy and save after sell service;
3.Full touch-screen enables intuitive operation by clicking one the specific parameters or the waveform in real time, standard configuration includes the navigation knob;
4.Real time S-T segment analysis, and ARR analysis;
5.SpO2 Pitch Tone Variation and Drug Dose Calculation;
6.Parameter waveform and characters color selectable
7.Multi-display: Standard, Large font, Trend Coexis, OxyCRG dynamic
8.Standby mode for Energy saving and suspend monitoring;
9.7-lead ECG waveforms display in phase;
10.Capture dynamic waveforms;
11.Built-in rechargeable lithium battery, and battery volume checking,
12.AC power checking
13.Efficient resistance to interference of defibrillator and HF knife;
14.SINNOR F-6 SpO2 technology, VS NELLCOR accuracy;
15.Networking capacity and TCP/IP networking platform enable abundant future upgrade
16.Time delay switch-off function keep the monitor data restart monitor;
17.Complete and flexible mounting solution for transportation and in-patient monitoring
18.SpO2 can work well In the condition of the low perfution of the patient
19.Can work in ICU, OR, ER
20.Permanent suspension of the Alarm with one button
Standard parameters: 5-lead ECG, SpO2,NIBP, TEMP,RESP,PR,HR.
6 Multi-parameters Patient monitor --- Multi-parameter Patient monitor

Function:
1.7" color TFT display, high resolution: 640X480dpi;
2.Full Separated para boards: Main board, ECG board, NIBPboard, SpO2 board, can guarantee the acccuracy and save after sell service;
3.Full touch-screen enables intuitive operation by clicking one the specific parameters or the waveform in real time, standard configuration includes the navigation knob;
4.Real time S-T segment analysis, and ARR analysis;
5.SpO2 Pitch Tone Variation and Drug Dose Calculation;
6.Parameter waveform and characters color selectable
7.Multi-display: Standard, Large font, Trend Coexis, OxyCRG dynamic
8.Standby mode for Energy saving and suspend monitoring;
9.7-lead ECG waveforms display in phase;
10.Capture dynamic waveforms;
11.Built-in rechargeable lithium battery, and battery volume checking,
12.AC power checking
13.Efficient resistance to interference of defibrillator and HF knife;
14.SINNOR F-6 SpO2 technology, VS NELLCOR accuracy;
15.Networking capacity and TCP/IP networking platform enable abundant future upgrade
16.Time delay switch-off function keep the monitor data restart monitor;
17.Complete and flexible mounting solution for transportation and in-patient monitoring
18.SpO2 can work well In the condition of the low perfution of the patient
19.Can work in ICU, OR, ER
20.Permanent suspension of the Alarm with one button
Standard parameters: 5-lead ECG, SpO2,NIBP, TEMP,RESP,PR,HR.
Performance Specifications:
Display | 7"color TFT Rolling and refreshing waveform display Resolution: 640X480 Multi display selectable including: Large-font display Trend coexist display OxyCRG dynamic view display. |
Trace | 9 waveforms(7 ECG, 1 SPO2 and 1 RESP) Sweep speed:12.5mm/s,25mm/s,50mm/s |
Indicator | Power/battery indicator light QRS beep and alarm sound |
Battery | Rechargeable lead acid cell, 12v/4AH Max.24 hour for charging, 4 hours for continue working |
Trend | Parameter graphic and tabular trends: 5s/piece,8 hours; 1min/piece,168 hours(24hour×7days) 5min/piece,1000 hours. |
Storage | NIBP: 1000 groups Alarm: 200 groups Full disclosure waveforms: 3600S SD card external storage |
Alarm | User-adjustable High, Medium and Low limits 3-level Audible and visual alarm |
Networking | Connected to central monitoring system TCP/IP netting platform |
Recorder | Build-in, thermal array Plethysmogram caveform:2 channels Record mode: manual, on alarm, time-defined Recording width: 50mm Printing speed: 50mm/s |
Recording type | Frozen waveform record NIBP recall record Trend table record Alarm record Fixed -time record |
Standard parameter:
ECG:
Lead mode: 5 -lead(R,L,F,N,C)
Lead selection : I,II,III,avR,avL,avF,V
Waveform: 3 and 7 channel selectable
Gain selection: 0.5mm/mv,1mm/mv,2mm/mv
Sweep speed: 6.25mm/s;12.5mm/s;25mm/s;50mm/s
Heart rate range: Adult: 15~300bpm;
Neonate/pediatric:15~350bpm
Accuracy: +1bpm or +1%,whichecer is greater
Resolution: 1bpm
Filter: surgery mode:1~20Hz
monitor model:0.5~40Hz
Diagnostic mode:0.05~130Hz
Scaling signal: 1mv,+3%
Protection: withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation
Alarm range: 15~350bpm
S-T segment detecton:
Measurement range: 2.0mV~+2.0mV
Alarm Range: -2.0mV~ +2.0mV
Accuracy: -0.8mV ~+0.8Mv
Error: +0.02Mv
Arrhythmia analysis: YES
SPO2
Measurement range: 0~100%
Resolution: 1%
Accuracy: +2%(70-100%);0-69% unspecified
Alarm range 0~100%
Pluse Rate:
range: 20~300bpm
Resolution: 1bpm
Error: +1bpm or +2%,whichever is greater
NIBP
RESPIRATION
Method:Thoracic impedance
Measurement range:Adult:7~120rpm;
Neonate/Pediatric:7~150rpm
Apnea alarm: YES,10~40s
Resolution:1rpm
Accuracy:+2rpm
TEMPERATURE
Compatible probe:YSI or CYF
Measurement range:5~50ºC
Resolution : 0.1ºC
Accuracy:+0.1ºC
Refreshing time:about 1
Average measuring time:<10s
FHR
Transducer:Multi-crystal, Pulsed Doppler
Measurement range: 50~210 BPM
Working frequency: 1 MHz
Strength: <5mW/cm[]
Signal processing:
special DSP system and modern recognization.
Resolution:1BPM
Accuracy:±1BPM
Alarm Range:High: 160,170,180,190 BPM,
Low: 100,110,120 BPM
ECG:
Lead mode: 5 -lead(R,L,F,N,C)
Lead selection : I,II,III,avR,avL,avF,V
Waveform: 3 and 7 channel selectable
Gain selection: 0.5mm/mv,1mm/mv,2mm/mv
Sweep speed: 6.25mm/s;12.5mm/s;25mm/s;50mm/s
Heart rate range: Adult: 15~300bpm;
Neonate/pediatric:15~350bpm
Accuracy: +1bpm or +1%,whichecer is greater
Resolution: 1bpm
Filter: surgery mode:1~20Hz
monitor model:0.5~40Hz
Diagnostic mode:0.05~130Hz
Scaling signal: 1mv,+3%
Protection: withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation
Alarm range: 15~350bpm
S-T segment detecton:
Measurement range: 2.0mV~+2.0mV
Alarm Range: -2.0mV~ +2.0mV
Accuracy: -0.8mV ~+0.8Mv
Error: +0.02Mv
Arrhythmia analysis: YES
SPO2
Measurement range: 0~100%
Resolution: 1%
Accuracy: +2%(70-100%);0-69% unspecified
Alarm range 0~100%
Pluse Rate:
range: 20~300bpm
Resolution: 1bpm
Error: +1bpm or +2%,whichever is greater
NIBP
Method | Digital Automatic oscillometric |
Operation mode | Manual/Automatic/continuous |
Auto measurement time | Adjustable(1~480min) |
Measurement Unit | mmHg/Kpa selectable |
Measurement types | Systolic, Diastolic, Mean |
Measurement tange | |
Range of Systolic pressure | Adult: 40~270mmHg Pediatric: 40~220mmHg Neonate: 40~135mmHg |
Range of mean pressure | Adult: 20~235mmHg Pediatric: 20~165mmHg Neonate: 20~110mmHg |
Range of diastolic pressure | Adult: 10~215mmHg Pediatric: 10~150mmHg Neonate :10~100mmHg |
Over-pressure protection | Double safety protection |
Resolution | 1 mmHg |
Alarm | Systolic.Diastolic,Mean |
RESPIRATION
Method:Thoracic impedance
Measurement range:Adult:7~120rpm;
Neonate/Pediatric:7~150rpm
Apnea alarm: YES,10~40s
Resolution:1rpm
Accuracy:+2rpm
TEMPERATURE
Compatible probe:YSI or CYF
Measurement range:5~50ºC
Resolution : 0.1ºC
Accuracy:+0.1ºC
Refreshing time:about 1
Average measuring time:<10s
FHR
Transducer:Multi-crystal, Pulsed Doppler
Measurement range: 50~210 BPM
Working frequency: 1 MHz
Strength: <5mW/cm[]
Signal processing:
special DSP system and modern recognization.
Resolution:1BPM
Accuracy:±1BPM
Alarm Range:High: 160,170,180,190 BPM,
Low: 100,110,120 BPM
FM
Manual button marking,
automatic FM identifying function
TOCO Measuring
Transducer: External pressure transducer
Measurement range: 0~100 units
Resolution: 1rpm
Accuracy: ±2 rpm
IBP
Channel: 2 channels
Range: -50-300mmHg
Resolution: 1mmHg
Accuracy: ±4mmHg(±4%)
Unit: mmHg, Kpa
Converter Sensitivity: 5V/V/mmHg
Transducer sites: ART/PA/CVP/LAP/RAP/ICP
EtCO2( Sidertream CO2)
Measurement range: 0~99mmHg
Accuracy: +2mmHg (0~40mmHg)
Sampling Range: 100ml/min
Sampling rate accuracy: 15%
Respiration rate: 0~120rmp
Respiration accuracy: +2rmp (0~70rmp)
+5rmp (>70rmp)
Respiration time: <240msec (10% to 90%)
Delay time: <2s
EtCO2 (mainstreaam CO2)
Method: Infrared Spectrum
Range: 0.0-10% (0~76%)
Resolution: 1mmHg (0.1%)
Accuracy: <5%(±4.0 mmHg)
Or<10%(of Readings)
Recorder:
Build-in, thermal array
Plethysmogram caveform:2 channels
Record mode: manual, on alarm, time-defined
Recording width: 50mm
Printing speed: 50mm/s
Recording type: Frozen waveform record
NIBP recall record
Trend table record
Alarm record
Fixed -time record

Miscellaneous
Satety:
Safety level: Class I, type CF
Dimendion: 28*42*48cm
G.Weight: <6.5KS
Operation Environment
Temperature: Working 0~+40ºC
Transportation and storage -20~+60ºC
Humidity: working≤85%
Transportation and storage≤93%
Power: AC 100-240,50/60Hz
Patient range: Neonate,pediatric,and adult patients
Accessories supplies
(1) 5 lead ECG cable
(2) 1 spo2 probes
(3) 1 NIBP prbe
(4) 1 temp probe
(5)1 ground connecting liner
(6) Chest electrode (10pcs/set)